The UKN Online UPS 6–10 kVA range is built for server rooms, technical rooms and industrial control, where a supply interruption is not acceptable. With an output power factor of 1.0, the rated kVA is fully available as kW: a 10 kVA unit feeds 10 kW of load. Efficiency reaches 94% at full load and 98% in ECO mode, which limits losses and heat in the cabinet.

The battery string is configurable from 16 to 20 blocks and can be replaced without shutting down the load. Up to four units run in parallel, for capacity or redundancy. The display rotates to suit rack or tower mounting. RS232 is standard, with SNMP, USB, RS485 and dry contacts as options.

Unik

  • Output power factor 1.0: 6 kVA = 6 kW, 10 kVA = 10 kW
  • Efficiency ≥ 94% at full load, up to 98% in ECO mode
  • Parallel operation up to 4 units, for capacity or redundancy
  • Flexible battery string, 16 to 20 blocks, hot-swappable

Datasheets & Docs

  • KCFF6AxPZHD

  • Lorem ipsum dolor sit amet, consectetur adipiscing elit

  • Lorem ipsum dolor sit amet, consectetur adipiscing elit

  • KCFF6AxPZHD

  • KCFF6AxPZHD

  • Lorem ipsum dolor sit amet, consectetur adipiscing elit

  • Lorem ipsum dolor sit amet, consectetur adipiscing elit

  • KCFF6AxPZHD

Specs

Dive into technicalities

  • Capacity6 kVA / 6 kW · 10 kVA / 10 kW
    TopologyOnline double conversion, high frequency
    InputSingle-phase (1Φ + N + PE), 208 / 220 / 230 / 240 Vac
    Input voltage range110–288 Vac (176–288 Vac without derating)
    Input frequency50 / 60 Hz auto-sensing, range 40–70 Hz
    Input power factor≥ 0.99
    Input THDi≤ 5 %
    Bypass voltage range−40 % to +15 % (settable)
    OutputSingle-phase (L-N), 208 / 220 / 230 / 240 Vac ± 1 %
    Output frequencySynchronized to bypass in mains mode; 50 / 60 Hz ± 0.1 % in battery mode
    WaveformPure sine wave
    Output power factor1.0
    Output THDv≤ 1 % (linear load), ≤ 4 % (non-linear load)
    Crest factor3:1
    Overload105–110 % for 10 min, 110–125 % for 1 min, 126–150 % for 30 s
    Battery voltage192 Vdc (192–240 Vdc settable), 16 blocks (16–20 settable)
    Built-in battery (standard model)16 × 12 V / 7 Ah (6 kVA), 16 × 12 V / 9 Ah (10 kVA)
    Charging currentStandard model: 1 A. Long-time model: 5 A default, 1–5 A settable, 12 A optional
    Recharge time90 % in 8 h (standard model)
    Efficiency≥ 94 % at 100 % load, max. 94.5 % at 60 % load, ≥ 98 % in ECO mode
    Transfer time0 ms
    Parallel operationUp to 4 units
    ProtectionsShort-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage, fan failure
    CommunicationsRS232 (standard); USB, RS485, dry contacts, SNMP, battery temperature compensation (optional)
    DisplayLCD + LED
    Operating temperature0 °C to 40 °C
    Relative humidity0–95 % (non-condensing)
    Altitude≤ 1000 m, derating 1 % per additional 100 m
    IP ratingIP20
    Noise level at 1 m≤ 55 dB (6 kVA), ≤ 58 dB (10 kVA)
    Dimensions W × D × HStandard model: 440 × 660 × 176 mm. Long-time model: 440 × 580 × 88 mm
    Net weight6 kVA: 58 kg (standard), 12 kg (long-time). 10 kVA: 63 kg (standard), 14 kg (long-time)